Proctor Compaction Test: Light vs Heavy, MDD and OMC Explained

A proctor compaction test finds the water content at which a soil packs down to its highest dry density. These two numbers, maximum dry density (MDD) and optimum moisture content (OMC), set the target for every layer rolled on site. If the lab values are wrong, every field density check is judged against the wrong target. This guide covers the IS 2720 methods, the procedure and the road limits.
Key takeaways
- A proctor compaction test gives two results: maximum dry density (MDD) and optimum moisture content (OMC).
- Light compaction follows IS 2720 (Part 7):1980 and drops a 2.6 kg rammer 310 mm onto 3 layers.
- Heavy compaction follows IS 2720 (Part 8):1983 and drops a 4.9 kg rammer 450 mm onto 5 layers.
- Heavy compaction uses about 4.5 times more energy, giving a higher MDD and lower OMC.
- MoRTH asks for at least 97% of heavy MDD in subgrades and 95% in embankments.
What is a proctor compaction test?
A proctor compaction test compacts the same soil at several water contents and records the dry density each time. Plotted against water content, the points form a curve with one peak. The height of that peak is the MDD, and the water content under it is the OMC.
Water lets the grains slide closer together. Past the optimum, however, water takes up space the grains could fill, so dry density falls. NPTEL covers the same lab procedure in its IIT soil mechanics course.
Light vs heavy compaction: what changes?
Both methods use the same mould but apply different energy. Light compaction matches the Standard Proctor test and is published by the Bureau of Indian Standards as IS 2720 (Part 7). Heavy compaction, the modified Proctor test, reflects the heavier rollers used on highways.
Parameter | Light (IS 2720 Part 7) | Heavy (IS 2720 Part 8) |
Rammer mass | 2.6 kg | 4.9 kg |
Free drop | 310 mm | 450 mm |
Layers | 3 | 5 |
Blows per layer (1,000 cm³ mould) | 25 | 25 |
Energy per m³ of soil | about 593 kJ | about 2,700 kJ |
Typical use | Building backfill, light fills | Roads, embankments, sub-base |
Energy is rammer weight × drop × total blows ÷ mould volume. For light compaction, 25.5 N × 0.31 m × 75 blows gives about 593 J per litre of soil. For gravelly soils, both methods switch to a 2,250 cm³ mould with more blows per layer.
Proctor compaction test procedure, step by step
- Prepare the sample. Air-dry the soil, break up the lumps and sieve it through the 19 mm IS sieve.
- Add water. Mix in a measured amount of water, starting well below the expected optimum, and mix it evenly.
- Compact in layers. Fill the mould in 3 layers for light compaction or 5 for heavy, and give each layer 25 evenly spread blows.
- Trim and weigh. Remove the collar, level the top with a straight edge, and weigh it.
- Find the water content. Take a representative sample from the specimen and oven-dry it.
- Add more water and compact again, using smaller steps near the peak, until the density clearly drops.
How to calculate MDD and OMC
Each specimen gives one point on the curve. Two formulas turn the weights into dry density.
Bulk density = (mass of mould with soil − mass of empty mould) ÷ mould volume
Dry density = bulk density ÷ (1 + w / 100)
Here, w is the water content in per cent. Plot dry density against water content and draw a smooth curve through the points. For example, if the curve peaks at 1.92 g/cm³ and 11.5% water, the MDD is 1.92 g/cm³ and the OMC is 11.5%.
Road specifications use kN/m³. Multiply g/cm³ by 9.81 to convert, so 1.92 g/cm³ is about 18.8 kN/m³.
What MDD and compaction do road works need?
For roads, the Ministry of Road Transport and Highways (MoRTH) sets targets in Section 300 of its Specifications for Road and Bridge Works (5th Revision), measured against heavy compaction to IS 2720 (Part 8).
Layer | Minimum lab MDD | Minimum field compaction |
Embankment up to 3 m, not subject to flooding | 15.2 kN/m³ | 95% of MDD |
Embankment over 3 m, or any height with long inundation | 16.0 kN/m³ | 95% of MDD |
Subgrade and earthen shoulders | 17.5 kN/m³ | 97% of MDD |
Expansive clays are not allowed in the subgrade. Granular sub-base must reach 98% of heavy MDD under Section 400, so the aggregate tests for that layer matter just as much.
Light or heavy: which test does your project need?
Use heavy compaction when the soil will carry traffic: road subgrades, embankments, granular sub-base and wet mix macadam. Light compaction suits building backfill and plinth filling, unless the drawings name a method.
The most common mistake is mixing the two. A field density checked against a light-compaction MDD looks better than it is, because light MDD is lower. Confirm the method before you send the sample.
Density checks also fail when the tested soil differs from the fill, or when rolling happens far from the OMC. Test each new borrow source and check moisture before rolling. Our soil testing lab can help you plan both.
Get Your Soil Tested at Jancy Labs
Jancy Labs Private Limited is an accredited civil material testing laboratory (ISO/IEC 17025:2017, Certificate No. TC-12176) in Madurai, Tamil Nadu. We collect samples across Tamil Nadu and accept courier samples from anywhere in India.
Or call +91 86800 49004 · jancylabsmdu@gmail.com · Request a quote
4.8★ · 100+ Google reviews · Mon–Sat, 10:00–18:00
Frequently Asked Questions
What is the difference between MDD and OMC?
MDD is the highest dry density a soil reaches under a set compaction effort. OMC is the water content at which that density occurs. Both values come from the same proctor compaction test curve.
Is the modified Proctor test the same as heavy compaction?
Yes. In India, heavy compaction to IS 2720 (Part 8) is the equivalent of the modified Proctor test. It uses a 4.9 kg rammer, a 450 mm drop and 5 layers.
How much soil does a proctor compaction test need?
Plan for about 5 kg of air-dried soil passing the 19 mm sieve for the standard mould. Gravelly soils, or soils that crush under the rammer, need larger samples.
Which compaction tests does Jancy Labs run?
Jancy Labs runs light compaction on soil, and heavy compaction on soil, granular sub-base and wet mix macadam. Each report gives the MDD and OMC.