CBR Test Lab

CBR Test Lab — Certified California Bearing Ratio Reports

NABL Accredited Laboratory (Certificate No. TC-12176) as per ISO/IEC 17025:2017

Your pavement design is ready. However, your consultant is asking for a certified CBR report. Jancy Labs is a professional CBR test lab delivering California Bearing Ratio reports as per IS 2720 Part 16 — every report signed by a qualified engineer and accepted by all government departments.

Certified CBR Testing as per IS 2720 Part 16 — Jancy Labs soil testing lab Madurai
Get Started

Your Project Is Waiting — Get Your CBR Report Today

Your pavement design is ready. However, your consultant is asking for a certified CBR report. Jancy Labs is a professional CBR test lab delivering California Bearing Ratio reports as per IS 2720 Part 16. Furthermore, every report is signed by a qualified engineer and accepted by all government departments. Get your CBR test done today →

Overview

What is the CBR Test?

The CBR test tells you the load-bearing strength of your subgrade soil — the critical value you need for pavement design. Furthermore, your CBR value directly determines the thickness of your road's base, sub-base, and surface layers. Therefore, an inaccurate CBR value leads to premature pavement failure, costly rework, or outright rejection by your approving authority.

Standards

Applicable Standards for California Bearing Ratio Testing

Jancy Labs conducts every California Bearing Ratio test strictly as per the following standards:

IS 2720 Part 16: 1987

Primary Indian standard for laboratory CBR testing. Following the correct standard ensures your CBR report is valid, defensible, and accepted without question.

Standard Referenced on Every Report

Therefore, Jancy Labs references the applicable standard explicitly on every single report — so your submission is defensible at every technical review stage.

Why It Matters

Why the CBR Test Matters for Your Road Project

  • PWD approval — Tamil Nadu PWD requires a certified CBR report before accepting any pavement design submission.
  • IRC:37 flexible pavement design — Mandatory Indian standard requiring CBR values for all road design.
  • NHAI & PMGSY compliance — Highway and rural road projects require CBR testing at defined intervals.
  • Southern Railway & AAI — Rail yard and airport pavement projects require CBR data for subgrade assessment.
  • Pavement cost control — Accurate CBR prevents over-designing layers, saving significant project costs.
  • Legal protection — Documented CBR results protect you if pavement performance disputes arise.

⚠️ Skipping or estimating CBR values almost always causes regulatory rejection and delays your entire project timeline. View all soil testing services →

Why Us

Why Choose Jancy Labs for CBR Testing?

When your road project depends on one number — the CBR value — you cannot afford an unreliable lab. Furthermore, Jancy Labs has the right equipment, the right engineers, and the right process for accurate CBR testing.

  • Calibrated CBR loading frame and penetration plunger — valid calibration certificates available.
  • California Bearing Ratio test conducted strictly as per IS 2720 Part 16 — no shortcuts.
  • CBR reports signed by qualified engineers with designation and lab stamp.
  • Reports accepted by Tamil Nadu PWD, NHAI, PMGSY, Southern Railway, and AAI.
  • Handles both soaked and unsoaked CBR testing as required by your project specification.
  • Trusted for CBR testing by highway contractors and road project managers across Tamil Nadu.

Jancy Labs is committed to accuracy, speed, and reports that clear regulatory scrutiny first time. Know about us → · NABL Accreditation details →

How It Works

How to Get Your CBR Test Done at Jancy Labs

01

Send Your Sample

Collect, pack, and dispatch your disturbed soil sample following the specifications below — moisture preservation is critical for accurate results.

02

We Test It

Your sample is registered, labelled, and assigned a unique test ID on arrival. Our engineers conduct every step of IS 2720 Part 16 — from sieving and compaction through soaking and penetration testing. All data is personally reviewed by a qualified engineer before any result is recorded.

03

You Receive Your Certified CBR Report

Digital copy by email for instant access; physical copy couriered on request. Accepted by PWD, NHAI, PMGSY, Southern Railway, and AAI.

Sample Quantity Required

  • Minimum 35 kg disturbed soil for a standard CBR test
  • Additional 5–10 kg if soaked CBR test required
  • Collect from proposed subgrade level — 500 mm below formation level
  • Remove all particles coarser than 19 mm before packing

How to Collect and Pack

  • Place soil in heavy-duty airtight polythene bag
  • Seal tightly — moisture preservation is critical for accurate results
  • Double bag for protection during transit
  • Label outer bag clearly with permanent waterproof marker
  • Undisturbed samples — use sealed PVC tubes, waxed at both ends

What to Include With Your Sample

  • Project name and full site address
  • Company name and direct contact number
  • Sample ID, collection point, and depth below ground
  • Date of sample collection
  • Test type — soaked CBR or unsoaked CBR
  • Consultant specifications or contract reference if applicable

How to Dispatch

  • Courier / Transport to Jancy Labs, No.6 Ganesh Nagar 3rd Street, Surya Nagar, Alagarkoil Mainroad, Madurai-625007
  • Direct drop-in during working hours 10AM to 6PM
  • WhatsApp tracking number to +91-9994421275
⏱ Turnaround time: 8 Days (Max)

Your CBR Report from Jancy Labs Includes

  • Sample identification and full project reference
  • Test standard: IS 2720 Part 16: 1987
  • Compaction details — moisture content and dry density
  • CBR value
  • Soaking period (soaked CBR test)
  • Authorised engineer's signature, designation, lab stamp
  • Official date of testing and report issue
Test Process

Our CBR Testing Process — as per IS 2720 Part 16

View our lab accreditation →

  1. Sample receipt and logging — Sample ID assigned, condition and quantity recorded.
  2. Sieve check — Material above 20 mm removed per IS 2720 Part 16 requirement.
  3. Moisture content determination — Natural moisture content of received sample measured.
  4. Proctor compaction — Soil compacted at OMC to required density in 150 mm CBR mould.
  5. Soaking (soaked CBR) — Sample submerged for 96 hours with surcharge weight applied; swell recorded daily.
  6. Penetration test — Plunger advanced at 1.25 mm/min; load recorded at standard intervals per IS 2720 Part 16.
  7. CBR value calculation — Load-penetration curve plotted; CBR calculated at 2.5 mm and 5.0 mm.
  8. Report preparation and sign-off — Results reviewed and certified report issued.
Every CBR test result is reviewed and signed by a qualified Geotechnical Engineer before dispatch.
Questions

Frequently Asked Questions

How long does a CBR test take at Jancy Labs?
The soaked CBR test requires 96 hours of soaking followed by the penetration test. Jancy Labs typically issues your certified CBR report within 8 working days of receiving your sample, including soaking time.
Can I send soil samples for CBR testing by courier to Jancy Labs?
Yes. Jancy Labs accepts soil samples for CBR testing sent by courier or transport service. Pack your sample in a sealed polythene bag inside a rigid container to prevent moisture loss during transit. Include your project name, site location, and collection depth.
Is your CBR test report accepted by Tamil Nadu PWD?
Yes. Jancy Labs CBR reports are issued as per IS 2720 Part 16 and are accepted by Tamil Nadu PWD, NHAI projects, and PMGSY road contractors. Every report carries the signature of a qualified Geotechnical Engineer and the Jancy Labs stamp.
Do you conduct both soaked and unsoaked CBR tests?
Yes. Jancy Labs conducts both soaked CBR and unsoaked CBR tests as per IS 2720 Part 16. Most highway and PWD projects require the soaked CBR value for pavement design. Specify which variant you need when submitting your sample.
How much soil do I need to send for a CBR test?
For a single CBR test as per IS 2720 Part 16, Jancy Labs requires a minimum of 6 kg of disturbed soil per test variant. If you need both soaked and unsoaked CBR, send at least 12 kg. Collect from the required subgrade depth and seal immediately after collection.
Get In Touch

Contact Jancy Labs — Get Your CBR Report

Submit your sample today and receive a certified CBR report that PWD, NHAI, PMGSY, Southern Railway, and AAI will accept — first time, every time.

ChannelDetail
📞 Call8680049004 / 9994421275
💬 WhatsApp8680049004
✉️ Emailjancylabsmdu@gmail.com
📍 VisitJancy Labs, No.6 Ganesh Nagar 3rd Street, Surya Nagar, Alagar Koil Mainroad, Madurai-07
🕐 HoursMonday to Saturday | 10:00 AM – 6:00 PM

Request Your CBR Test

Leave your details and our team will call you back to confirm sample dispatch and turnaround.

Scroll to Top